Prosoft-technology MVI69-ADM Uživatelský manuál Strana 154

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 342
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 153
Application Development Function Library - ADM API MVI-ADM 'C' Programmable
Developer's Guide 'C' Programmable Application Development Module
Page 154 of 342 ProSoft Technology, Inc.
February 20, 2013
ADM_DBSwapWord
Syntax
int ADM_DBSwapWord(ADMHANDLE adm_handle, unsigned short offset)
Parameters
adm_handle
Handle returned by previous call to ADM_Open
offset
Word offset into database where swapping is to be performed
Description
This function swaps bytes within a database word.
adm_handle must be a valid handle returned from ADM_Open.
Return Value
ADM_SUCCESS
No errors were encountered
ADM_ERR_NOACCESS
adm_handle does not have access
ADM_ERR_MEMORY
database is not allocated
ADM_ERR_REG_RANGE
offset is out of range
Example
ADMHANDLE adm_handle;
unsigned short offset;
ADM_DBSwapWord(adm_handle, offset);
Zobrazit stránku 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 341 342

Komentáře k této Příručce

Žádné komentáře