MVI-ADM ♦ 'C' Programmable Application Development Function Library - ADM API
'C' Programmable Application Development Module Developer's Guide
ProSoft Technology, Inc. Page 129 of 342
February 20, 2013
ADM_DAWriteRecvData
Syntax
int ADM_DAWriteRecvData(ADMHANDLE adm_handle, ADM_INTERFACE *adm_interface_ptr,
int app_port, int length, char *data_buff);
Parameters
Handle returned by previous call to ADM_Open
Pointer to ADM_INTERFACE structure which contains structure
pointers needed by the function
Application serial port referenced
The number of data characters to send to the data analyzer
The buffer holding the receive data
Description
This function sends receive data to the data analyzer screen. The data will
appear between two square brackets: [data].
adm_handle must be a valid handle returned from ADM_Open.
MVI94 Note
Only application port 0 is valid for the MVI94.
Return Value
No errors were encountered
adm_handle does not have access
Example
ADMHANDLE adm_handle;
ADM_INTERFACE *interface_ptr;
ADM_PORT ports[MAX_APP_PORTS];
Int app_port;
ADM_INTERFACE interface;
interface_ptr = &interface;
ADM_DAWriteRecvData(adm_handle, interface_ptr, app_port, ports[app_port].len,
ports[app_port].buff);
See Also
ADM_DAWriteSendData (page 128)