MVI56E-GSC CompactLogix or MicroLogix Platform Start Here
Enhanced Generic ASCII Serial Communication Module User Manual
ProSoft Technology, Inc. Page 23 of 140
May 9, 2014
Note: For alternative methods of connecting to the module with your PC, refer to Using
CIPconnect
®
to Connect to the Module (page 25) or Using RSWho to Connect to the Module (page
33).
These steps show you how to set a permanent IP address on the module. This
example assumes module’s default IP address is 192.168.0.250.
1 Start ProSoft Configuration Builder.
2 Select the MVI56E-GSC icon, and then click the [+] symbol to expand the
MVI56E-GSC tree.
3 Select ETHERNET CONFIGURATION, and then click the right mouse button to
open a shortcut menu.
4 On the shortcut menu, select CONFIGURE.
This action opens the Edit-WATTCP dialog box. Use this dialog box to enter
the MVI56E-GSC module’s permanent IP Address (MY_IP), SUBNET MASK
(NETMASK) and DEFAULT GATEWAY (GATEWAY).
5 Click OK to save the updated Ethernet configuration.