Prosoft-technology AN-X2-SQD Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Relé Prosoft-technology AN-X2-SQD. ProSoft Technology AN-X2-SQD User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 51
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
AN-X2-SQD-MAS
Square D Remote I/O
Scanner Module
User Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 50 51

Shrnutí obsahu

Strany 1 - User Manual

AN-X2-SQD-MAS Square D Remote I/O Scanner Module User Manual

Strany 2

Page 4 AN-X2-SQD-MAS June 2013 Installation Prevent Electrostatic Discharge The module is sensitive to electrostatic discharge. WARNING! Electrosta

Strany 3

AN-X2-SQD-MAS Page 5 Pin Assignment 1 RIO 2 2 RIO 1 3 shield 4 RIO 4 5 RIO 3 Ensure that the physical ends of the remote I/O network are pro

Strany 4

Page 6 AN-X2-SQD-MAS June 2013 Quick Start Step See page 1 Power up the AN-X, connect it to Ethernet and assign it an IP address 6 2 Connect A

Strany 5 - USING THE WEB INTERFACE 29

AN-X2-SQD-MAS Page 7 Ethernet Configuration Before you can use the AN-X2-SQD-MAS, you must configure its network properties on Ethernet. Initial Et

Strany 6 - WARRANTY 45

Page 8 AN-X2-SQD-MAS June 2013 Select Administration/AN-X Configuration. The AN-X2 Configuration page appears.

Strany 7 - Module Overview

AN-X2-SQD-MAS Page 9 At the top the screen shows the serial number and MAC address of the AN-X being configured. Check either DHCP or Static. DHCP

Strany 8 - Package Contents

Page 10 AN-X2-SQD-MAS June 2013 Hostname Enter a Hostname for the AN-X2. This name is used internally by AN-X and may be used to identify the AN-X

Strany 9 - AN-X2 Modes of Operation

AN-X2-SQD-MAS Page 11 Reconfiguring an AN-X from an Unknown State It sometimes happens that an AN-X has been previously configured with an IP addres

Strany 10 - Installation

Page 12 AN-X2-SQD-MAS June 2013 Example: DHCP IP: DHCP Hostname: ANX2SqdMas Firmware: AN-X2-SQD-MAS Example: static IP address IP: 192.168.1.14 Net

Strany 11 - Software Installation

AN-X2-SQD-MAS Page 13 Default Gateway: 10.10.0.1 =========================================================================== Persistent Rout

Strany 12 - Quick Start

Page ii AN-X2-SQD-MAS June 2013 Because of the variety of uses for the products described in this publication, those responsible for the application

Strany 13 - Ethernet Configuration

Page 14 AN-X2-SQD-MAS June 2013 Remote I/O Network Configuration Before you can scan a Square D Remote I/O network, you must configure the network i

Strany 14

AN-X2-SQD-MAS Page 15 Description Input Registers Output Registers Type Code RIM331 32 IN DC (D5) 2 0 0xD5 RIM101 16 IN AC/DC 1 0 0xE0 RIM3

Strany 15 - Static IP Address

Page 16 AN-X2-SQD-MAS June 2013 AN-X also generates a ControlLogix data mapping configuration based on the I/O it finds (see page 19) and generates

Strany 16 - Firmware

AN-X2-SQD-MAS Page 17 Parameter Keyword Valid entries Drop number Drop= 1-8 Slot number Slot= 1-16 Input Registers InpRegs= Number of regis

Strany 17 - The Configuration File

Page 18 AN-X2-SQD-MAS June 2013 Viewing the Current Configuration To view the Remote I/O configuration currently in AN-X, access the web interface a

Strany 18

AN-X2-SQD-MAS Page 19 Exchanging Scheduled Data with a ControlLogix The AN-X2-SQD-MAS supports multiple scheduled connections with a ControlLogix p

Strany 19 - AN-X2-SQD-MAS Page 13

Page 20 AN-X2-SQD-MAS June 2013 The ClxName consists of a line with the keyword ClxName, followed by a comma and the name you give the emulated ENBT

Strany 20 - Supported Modules

AN-X2-SQD-MAS Page 21 Example: To map the outputs from drop 1 slot 4 to ControlLogix offset 27, add the following line to the DataOutput section of

Strany 21 - Autoconfiguration

Page 22 AN-X2-SQD-MAS June 2013 Starting Offset Description 50 Connection 1 statistics … 190 Connection 15 statistics Diagnostic Counters The

Strany 22 - Manual Configuration

AN-X2-SQD-MAS Page 23 Offset Counter 4 UDP Tx Busy 5 UDP Rx Busy Connection Statistics The AN-X module maintains statistics for each scheduled c

Strany 24

Page 24 AN-X2-SQD-MAS June 2013 DataOutput ; Outputs from ControlLogix 0 d8s02 ; 0->0 ( 1) "ROM221 16 OUT AC" 1 d8s03 ; 1-&

Strany 25 - Mapping I/O Data

AN-X2-SQD-MAS Page 25 Set the Name to match the hostname of the AN-X in the Ethernet configuration. Set the chassis size to 17 and the Slot to 16.

Strany 26 - ClxSlot, 0

Page 26 AN-X2-SQD-MAS June 2013 Set the parameters as shown. Set the Slot to 0 for the first connection, 1 for the second connection, and so on.

Strany 27 - Diagnostic Data

AN-X2-SQD-MAS Page 27 ControlLogix Aliases AN-X uses the Ethernet/IP configuration to create aliases that can be imported into RSLogix 5000. Use t

Strany 28 - UDP Connection Diagnostics

Page 28 AN-X2-SQD-MAS June 2013

Strany 29 - Example Configuration File:

AN-X2-SQD-MAS Page 29 Using the Web Interface The AN-X module contains a webserver capable of communicating with standard web browsers such as Inter

Strany 30

Page 30 AN-X2-SQD-MAS June 2013 Chrome, Private browsing in Firefox and Safari, etc.) Automation Network Remote Network Select Automation Network/

Strany 31 - AN-X2-SQD-MAS Page 25

AN-X2-SQD-MAS Page 31 Configure ControlLogix Support AN-X exchanges scheduled data with a ControlLogix processor over Ethernet. Refer to section Ex

Strany 32

Page 32 AN-X2-SQD-MAS June 2013 Click on the links to view the files. Right click on the links to retrieve the files from AN-X and store them on yo

Strany 33 - Using the ControlLogix Log

AN-X2-SQD-MAS Page 33 Click the Ethernet/IP link to view the current ControlLogix configuration.

Strany 34 - 28 AN-X2-SQD-MAS June 2013

MODULE OVERVIEW 1 Hardware Features 2 Package Contents 2 Using the MicroSD Card 3 AN-X2 Modes of Operation 3 INSTALLATION 4 Prevent Electrostatic D

Strany 35 - Using the Web Interface

Page 34 AN-X2-SQD-MAS June 2013 Log Files AN-X maintains various logs to record diagnostic and error messages. Use the Log Files menu in the web in

Strany 36 - Automation Network

AN-X2-SQD-MAS Page 35 The top of the screen shows the serial number and MAC Address of the AN-X2 being configured. Check either DHCP or Static. DHCP

Strany 37 - View Configuration Files

Page 36 AN-X2-SQD-MAS June 2013 Click the Archive File link and enter a filename and location. Update AN-X Firmware Use Update AN-X Firmware to d

Strany 38 - View Active Configuration

AN-X2-SQD-MAS Page 37 Browse to select the file, then click the Update Firmware button to transfer the file. WARNING! It is essential that you do n

Strany 39 - AN-X2-SQD-MAS Page 33

Page 38 AN-X2-SQD-MAS June 2013 . Click the Restart Now link to restart the AN-X. Troubleshooting Menu The troubleshooting menu contains informati

Strany 40 - Administration Menu

AN-X2-SQD-MAS Page 39 Troubleshooting LEDs The AN-X2-SQD-MAS has LEDs that indicate the state of the Ethernet connection, the overall module state

Strany 41 - Archive Configuration

Page 40 AN-X2-SQD-MAS June 2013 “Railroading” – SYS (or MS) and NET (or NS) LEDs AN-X alternates (railroads) flashing the SYS (or MS) and NET (or NS

Strany 42 - Update AN-X Firmware

AN-X2-SQD-MAS Page 41 Debug Mode SYS or MS LED The SYS or MS LED is used by the AN-X operating system and software to indicate the state of operati

Strany 43 - Restart AN-X Module

Page 42 AN-X2-SQD-MAS June 2013 Updating the Firmware The AN-X2 operating software consists of the maintenance firmware and the runtime firmware. Th

Strany 44 - Troubleshooting Menu

AN-X2-SQD-MAS Page 43 Specifications Parameter Specification Function Bridge between Ethernet and Remote network Typical Power Consumption 225 m

Strany 45 - Troubleshooting

AN-X2-SQD-MAS Page iii Autoconfiguration 15 Manual Configuration 16 Remote I/O Configuration File Format 16 Viewing the Current Configuration 18 Sav

Strany 46 - MS and NS LEDs: Runtime

Page 44 AN-X2-SQD-MAS June 2013 Support How to Contact Us: Sales and Support Sales and Technical Support for this product are provided by ProSoft T

Strany 47 - Fatal Errors

AN-X2-SQD-MAS Page 45 Warranty Quest Technical Solutions warrants its products to be free from defects in workmanship or material under normal use a

Strany 48 - Updating the Firmware

Page iv AN-X2-SQD-MAS June 2013 Administration Menu 34 AN-X Configuration 34 Submitting the Configuration 35 Archive Configuration 35 Update AN-X Fi

Strany 49 - Specifications

Module Overview The AN-X2-SQD-MAS communications module connects to a ControlLogix PLC over Ethernet/IP and acts as a scanner on the Square D remot

Strany 50 - Support

Page 2 AN-X2-SQD-MAS June 2013 Hardware Features The module has: • LEDs to indicate the status of the connection to the Ethernet (100 and Link/A

Strany 51 - Warranty

AN-X2-SQD-MAS Page 3 Using the MicroSD Card The AN-X2 microSD card stores configuration data and firmware. The are no restrictions on the size or s

Komentáře k této Příručce

Žádné komentáře